Swimming Pool Heat PumpsHeat Pump Tool Box Quick Reference Guide
HYDRAULICSAlternate Heat Source 10
HYDRAULICS 11BRANCH MAIN BRANCH MAIN BRANCH MAIN15 GPM 1-1/2" 1-1/2" 15 GPM 1-1/2" 1-1/2" 15 GPM 1-1/2" 2"30 1-1/
Electrical Data 12ELECTRICAL 12MODEL NO. VAC in. - PHASE - Hz MINIMUM CIRCUITAMPACITY (A)MAXIMUM BREAKER SIZE (A)2350 208/230 - 1 - 60
13ELECTRICALMaximum Wire LengthFrom Breaker to Heater* This chart is only a guide, based on NEC calculations. State and local codes must beap
ELECTRICALElectrical Hook Up 14
ELECTRICAL 15Electrical Wiring DiagramElectrical wiring diagram is locatedunderneath the main terminal bar, behindthe electrical access panel
ELECTRICAL 16Temp. Sensor 10k Conversion⁰FOHMS⁰FOHMS⁰FOHMS⁰FOHMS58 16,123 72 11,305 85 8,249 98 6,09759 15,711 73 11,029 86 8,056 99 5,96060 15
ELECTRICAL 17Temp. Sensor 5K Conversion⁰FOHMS⁰FOHMS50 9,950 79 4,78754 9,045 82 4,38957 8,230 86 4,02961 7,500 90 3,70264 6,840 93 3,40468 6,24
18ANALOG CONTROLS1. Verify that the power lamp is ON and that the pool/spa pump is running and circulating properly.2. Verify that the control
ANALOG CONTROLS 19Power (amber lamp): When lit, indicates power is applied to the unit.Analog ControlWater Flow (green lamp): When lit, indicat
2For your health and the protection of your pool equipment, it is essential that your waterbe chemically balanced. The following levels must b
Thermostat SettingDIGITAL CONTROLS 20Want to make the Board a “Pool ONLY” Board? Please call 800-260-2758 for instructions.Press the SET key
DIGITAL CONTROLS 21Water TemperaturePress the SET key until you see POL is for pool and SPA is for spa. The current programmed temperature will
DIGITAL CONTROLS 22Press the SET key until you see the F-C on the screen.Press up and down arrow keys.Select either F (Farenheit) or C (Celsius
DIGITAL CONTROLS 23Digital Start Up1. Verify that the digital board is displaying a temperature, the pool pump is running andwater is circulati
24DIGITAL CONTROLSPress the SET key until you see the H-C on screenPress up and down arrow keys to select HEA (heat), COL (cool), or AUT (auto
DIGITAL CONTROLS 25Digital Fault code-OFFThe desired programmed temperature point is lowerthan 60°F (15°C).
Digital Fault Code-LPDIGITAL CONTROLS 26Shortage of refrigerant gas in the unit or faulty lowpressure control. The unit will show (LP3) after 3
DIGITAL CONTROLS 27Digital Fault code-HPThe high pressure switch within the refrigerant circuithas been engaged. This is usually a result of l
Digital Fault Code-FLO 28DIGITAL CONTROLSPossible causes:• The filter is in backwash position• The filter pump is stopped.• The filter is dirty
DIGITAL CONTROLS 29Digital Fault code-FSUnit is in the defrosting cycle which means that thefan is operating but the compressor has beenstopped
3Model Number and Serial Number LocationBefore you call Raypak service, make sure you have the MODEL NUMBER and SERIAL NUMBER.Model & Seri
30DIGITAL CONTROLSDigital Fault Code --Keypad is pressing down on both buttons. Keypad needs replacement.
31ELECTRICAL AUTOMATIONElectrical Automation2-Wire ControllerConnect the two wires fromthe automation device tothe TOTAL and COMMONconnections
32ELECTRICAL AUTOMATIONAnalog ControlHeat pump with analog controls• Set the MODE selector dial to “REMOTE”• Set both THERMOSTATS to the highe
33ELECTRICAL AUTOMATIONDigital ControlMake sure heat pump pool heater is disabled on automation controller. Push the SET key until “POL” is di
34TROUBLE SHOOTINGCheck power supply:• Is the power light or digital display on?• Is the circuit breaker assigned to the heat pump in the righ
35TROUBLE SHOOTINGUnit Not HeatingDoes the Ejected Air from the unit feel 8 to 10degF cooler that the outsideTemp? This is your first indicato
Unit LeakingTROUBLE SHOOTING 36Heat pumps can produce a large amount of condensation during operation. Shut OFFHeat pump BUT leave pool pump ON
TROUBLE SHOOTING 37Unit Not Talking With AutomationTake the heat pump out of “Remote Mode” to verify functionality• If the unit begins to func
38TROUBLE SHOOTINGRefrigerant TestingCompoundGaugeHigh PSIGaugeLow PSI / VACEvacuate / ChargeHigh PSILicensed HVAC Contractors: Temperature/Pr
Heat Pump Sizing Programvisit www.raypak.com or www.rheem.com/prodcuts/pool_spa
OUTDOOR ONLYTOP: 60”BACK: 12”FRONT: 24”LEFT SIDE: 12”RIGHT SIDE: 12”FLOOR: 0”Clearances - GeneralPLACEMENT 4
Heat Pump Tool Box Quick Reference GuideHeat pump not running? Did you check the power supply, the thermostat and automation temperature settings, &am
Heat Pump Placement60” (1.52m)MIN12” (0.3m)MIN3 ft. (0.9m)MINAS EASY AS 1, 2, 3• 1 ft. (12 in.) clearance for airflow into the unit• 2 ft. (24 in.) cl
Placement - 5350 thru 10353PLACEMENT 6When placing the unitavoid:• Roof water runoff: use gutters or diverters.• Water from sprinkler sytems:Ca
Placement - 2350,3350,4350PLACEMENT 7PAD SPECIFICATION:GREATER THAN OR EQUAL TO 2-1/2” THICK SOLID CONCRETE 3000 P. S. I. OR GREATER LOAD RATIN
Single Unit PlumbingHYDRAULICS 8For systems within flow requirementsFor Systems with flow that is difficult toregulate or that exceed requireme
HYDRAULICS 9Hydraulic PerformanceRAYPAK / RHEEM 5350Ti & 5310TiFlow RatePressureDrop: PSIPressureDrop: TDH10 1 220 2 530 4 940 7 1650 10 23